產(chǎn)品詳情
SBD50技術(shù)選型參數(shù)
|
|
二級(jí)減速 |
公稱(chēng)速比 |
輸出轉(zhuǎn)速 |
電機(jī)功率 |
輸出轉(zhuǎn)矩 |
許用扭矩 |
使用系數(shù) |
||||||
|
|
48.375 |
29.35 |
1.1 |
302.76 |
800 |
2.64 |
|||||||
|
|
59.125 |
24.02 |
1.1 |
370.04 |
800 |
2.16 |
|||||||
|
|
91.375 |
15.54 |
1.1 |
571.88 |
800 |
1.40 |
|||||||
|
|
102.125 |
13.90 |
1.1 |
643.85 |
800 |
1.24 |
|||||||
|
|
123.625 |
11.49 |
1.1 |
773.72 |
800 |
1.03 |
|||||||
|
|
155.875 |
9.11 |
0.75 |
665.16 |
800 |
1.20 |
|||||||
|
|
188.125 |
7.55 |
0.75 |
802.77 |
800 |
1.00 |
|||||||
|
|
209.625 |
6.77 |
0.75 |
894.51 |
800 |
0.89 |
|||||||
|
|
231.125 |
6.14 |
0.55 |
723.26 |
800 |
1.11 |
|||||||
|
|
252.625 |
5.62 |
0.55 |
790.54 |
800 |
1.01 |
|||||||
|
|
317.125 |
4.48 |
0.55 |
992.38 |
800 |
0.81 |
|||||||
|
|
三級(jí)減速 |
358.445 |
3.96 |
0.55 |
1099.67 |
1000 |
0.91 |
||||||
|
|
435.375 |
3.26 |
0.55 |
1252.27 |
1000 |
0.80 |
|||||||
|
|
532.125 |
2.67 |
0.37 |
1008.19 |
1000 |
0.99 |
|||||||
|
|
553.961 |
2.56 |
0.37 |
1143.30 |
1000 |
0.87 |
|||||||
|
|
619.133 |
2.29 |
0.37 |
1277.81 |
1000 |
0.78 |
|||||||
|
|
650.375 |
2.18 |
0.25 |
850.31 |
1000 |
1.18 |
|||||||
|
|
749.476 |
1.89 |
0.25 |
1002.10 |
1000 |
1.00 |
|||||||
|
|
822.375 |
1.73 |
0.25 |
1052.78 |
1000 |
0.95 |
|||||||
|
919.125 |
1.54 |
0.25 |
1176.64 |
1000 |
0.85 |
|
|||||||
|
1005.125 |
1.41 |
0.25 |
1286.73 |
1000 |
0.78 |
|
|||||||
|
1140.508 |
1.25 |
0.25 |
1590.44 |
1000 |
0.63 |
|
|||||||
|
1270.852 |
1.12 |
0.25 |
1772.21 |
1000 |
0.56 |
|
|||||||
|
1359.875 |
1.04 |
0.25 |
1740.87 |
1000 |
0.57 |
|
|||||||
|
1401.195 |
1.01 |
0.25 |
1952.97 |
1000 |
0.51 |
|
|||||||
|
1531.539 |
0.93 |
0.25 |
2047.67 |
1000 |
0.49 |
|
|||||||
|
1736.125 |
0.82 |
0.25 |
2222.54 |
1000 |
0.45 |
|
|||||||
|
1922.570 |
0.74 |
0.25 |
2570.48 |
1000 |
0.39 |
|
|||||||
SBD65P-B-Φ45速比102功率2.2KW 減速機(jī)現(xiàn)貨

下面我們舉個(gè)例子帶大家了解一下冷卻塔工作的過(guò)程。圓形逆流式冷卻塔的工作過(guò)程為例:熱水自主機(jī)房通過(guò)水泵以一定的壓力經(jīng)過(guò)管道、橫喉、曲喉、中心喉將循環(huán)水壓至冷卻塔的播水系統(tǒng)內(nèi),通過(guò)播水管上的小孔將水均勻地播灑在填料上面;干燥的低晗值的空氣在風(fēng)機(jī)的作用下由底部入風(fēng)網(wǎng)進(jìn)入塔內(nèi),熱水流經(jīng)填料表面時(shí)形成水膜和空氣進(jìn)行熱交換,高濕度高晗值的熱風(fēng)從頂部抽出,冷卻水滴入底盆內(nèi),經(jīng)出水管流入主機(jī)。一般情況下,進(jìn)入塔內(nèi)的空氣、是干燥低濕球溫度的空氣,水和空氣之間明顯存在著水分子的濃度差和動(dòng)能壓力差,當(dāng)風(fēng)機(jī)運(yùn)行時(shí),在塔內(nèi)靜壓的作用下,水分子不斷地向空氣中蒸發(fā),成為水蒸氣分子,剩余的水分子的平均動(dòng)能便會(huì)降低,從而使循環(huán)水的溫度下降。
SBD65技術(shù)選型參數(shù)
|
二級(jí)減速 |
公稱(chēng)速比 |
輸出轉(zhuǎn)速 |
電機(jī)功率 |
輸出轉(zhuǎn)矩 |
需用扭矩 |
使用系數(shù) |
|
|
|
36 |
39.44 |
3 |
624.65 |
1200 |
1.92 |
|
|
|
44 |
32.27 |
3 |
763.46 |
1200 |
1.57 |
|
|
|
48.375 |
29.35 |
3 |
839.37 |
800 |
0.95 |
|
|
|
59.125 |
24.02 |
3 |
1025.90 |
800 |
0.78 |
|
|
|
68 |
20.88 |
3 |
1179.90 |
1200 |
1.02 |
|
|
|
二級(jí)減速 |
公稱(chēng)速比 |
輸出轉(zhuǎn)速 |
電機(jī)功率 |
輸出轉(zhuǎn)矩 |
|
|
|
|
44 |
32.27 |
3 |
763.46 |
1200 |
|
|
|
155.875 |
9.11 |
1.1 |
975.56 |
800 |
0.82 |
|
|
|
172 |
8.26 |
1.1 |
1076.48 |
1200 |
1.11 |
|
|
|
188.125 |
7.55 |
1.1 |
1177.40 |
800 |
0.68 |
|
|
|
209.625 |
6.77 |
1.1 |
1311.96 |
800 |
0.61 |
|
|
|
231.125 |
6.14 |
1.1 |
1446.03 |
800 |
0.55 |
|
|
|
236 |
6.02 |
1.1 |
1477.03 |
1200 |
0.81 |
|
|
|
252.625 |
5.62 |
0.75 |
1076.41 |
800 |
0.74 |
|
|
|
284 |
5.00 |
0.75 |
1211.90 |
1200 |
0.99 |
|
|
|
317.125 |
4.48 |
0.75 |
1353.25 |
800 |
0.59 |
|
|
|
381.625 |
3.72 |
0.75 |
1626.76 |
800 |
0.49 |
|
|
SBD65P-B-Φ45速比102功率2.2KW 減速機(jī)現(xiàn)貨

選礦廠(chǎng)除塵器各部件的維護(hù)布袋:定期對(duì)凈氣室和濾袋檢查,查看有無(wú)積灰、水汽和銹斑。一旦有上述情況發(fā)生,就說(shuō)明一濾袋破損或操作條件不對(duì)。清灰機(jī)構(gòu):和除塵器其他部件一樣,清灰機(jī)構(gòu)不需要定期服務(wù),然而,我們建議利用有的間隙期對(duì)其進(jìn)行檢查。查看軸承、螺絲有無(wú)松、壞。除塵器狀況選礦廠(chǎng)除塵器安裝使用后,一定不要對(duì)除塵器殼體進(jìn)行電焊,切割。但焊接前一定要拆除濾袋或蓋住濾袋以防止焊接火花的傷害,這類(lèi)傷害對(duì)濾袋而言可能是致命的。頻電爐維修開(kāi)爐前的檢查工作檢查坩堝內(nèi)惻壁爐襯和出鐵口交界處有無(wú)裂縫,坩堝底及渣線(xiàn)部位爐襯有無(wú)局部蝕損。檢查感應(yīng)線(xiàn)圈表面、匝間、底部有無(wú)導(dǎo)電塵霜和鐵液飛濺物,須清除干凈。試運(yùn)行油泵,檢查液壓系統(tǒng)壓力及泄漏,檢查傾爐裝置和爐蓋動(dòng)作是否靈活、平穩(wěn)發(fā)現(xiàn)問(wèn)題及時(shí)解決。坩堝內(nèi)裝入適當(dāng)爐料,打開(kāi)外循環(huán)水源閥門(mén),使水分配器進(jìn)水壓力表指示達(dá)到設(shè)計(jì)要求(一般為.2-.3MPa),觀察感應(yīng)線(xiàn)圈、水冷電纜、上下水冷圈、磁軛、短路環(huán)等各支路水流量(是否暢通),進(jìn)水溫度是否達(dá)到要求(高于5℃,低于35度):?jiǎn)?dòng)內(nèi)循環(huán)水泵,使中頻電源柜內(nèi)其進(jìn)水壓力表指示O.lMPa,并觀察各支路回水是否暢通;檢查水箱水位,若低于下限水位應(yīng)補(bǔ)充純凈水至上位水限(嚴(yán)禁添加自來(lái)水),檢查內(nèi)外循環(huán)各支路管路是否老化、破損、滲漏、堵塞等,發(fā)現(xiàn)問(wèn)題及時(shí)處理、2中頻電爐維修開(kāi)機(jī)、停機(jī)操作()合上進(jìn)線(xiàn)低壓柜開(kāi)關(guān),觀察三相進(jìn)線(xiàn)電壓表指示是否正常;將調(diào)功電位器旋鈕調(diào)至小位,按控制電源接通鈕,經(jīng)2-3s后,按主電路接通鈕,再按逆變起動(dòng)鈕,中頻電源開(kāi)始工作,直流電壓表、電流表、中頻頻率表、功率表均有指示。