產(chǎn)品詳情
東麗膜優(yōu)于并可替代陶氏HSRO-4040-FF曾用名SG30-85-HS:
1、東麗外接式接頭陶氏內(nèi)接式(需更換膜與膜殼之間的適配器)
2、陶氏壓力10.5MPA,東麗0.75MPA(陶氏操作壓力高,耗能)
3、陶氏單層玻璃鋼外殼,易破碎。
MODEL SUL-G20TS
Salt
Rejection:99.5%;Product Flow Rate:30m3/day (7900gpd)
1. Test Conditions
Feed Water Pressure 0.75
MPa (110 psi)
Feed Water Temperature
25 °C (77 °F)
Feed Water Concentration
500 mg/ as NaCl
Brine Flow Rate 80
/min. (5.3 gpm)
Feed Water pH 6.5
2. 99.0 % minimum*
3. 24 m3/day (1100 gpd) minimum*
*For any single element
Design
Conditions
Feed Water Pressure <1.0 MPa (150
psi)
Feed Water Temperature <35 °C (95
°F)
Feed Water Turbidity ( SDI ) <4
Feed Water pH Range, Continuous Operation 3-9
Feed Water pH Range, Chemical Cleaning 2-11
Feed Flow Rate per Vessel <200/min. (52
gpm)
Brine Flow Rate per Vessel > 40/min.
(11 gpm)
Brine/Permeate Flow Ratio>6
Pressure Drop ( per Element ) <0.10 MPa
(14 psi)
Pressure Drop ( per Vessel ) <0.20 MPa
(29 psi)




